PRODUCTS

100 kW Resistive Load Bank

Resistive load bank is a device which can simulate the real-life resistive loads and provides a rigorous test regime for power supplies from 1kW to 60MW. The “load” of a resistive load bank is created by the conversion of electrical energy to heat by power resistors. It mainly used to test and maintenance of Engine Generators, Storage Battery Systems, UPS Systems, Inverters, Ground Power Units, Auxiliary Power Units, Aircraft Power Generators, Wind Generators, Hydro Generators etc.

Resistive load bank are available in stationary type for permanent installation or portable type with lifting rings, castors. Larger load banks, typically above 1700KW, are based on an ISO container construction. Special finishes including custom paint colors and stainless steel casings can be supplied.

loadbank
losdbank1
028475736bac8361093aafd6f90e234
loadbank losdbank1 028475736bac8361093aafd6f90e234

Main features

  1. Multiple control mode: (1) manual panel control (2) remote controller (3)PC software control
  2. Multiple display function: voltage, current, frequency, power factor, active power, reactive power, apparent power etc.
  3. Multiple protection function: overvoltage, overcurrent, overheat, over low blowing rate, blower overheat, blower phase sequence reverse protection, smoke alarm etc.
  4. Forced air cooling: industrial heavy duty fan, horizon air intake, upwards outlet, low noise.
  5. Power consumption components: made by special alloy resistance, high temperature resisting, high heat dissipation capability, high heat stability, no naked light, safety and reliability. Running temperature is 1/3 of rating.
  6. Weather-proof structure: containerized structure provides ultra protection, protection grade higher than IP54.
  7. Material and coating: the body adopt cold-rolled steel plate that processed by galvanizing corrosion protection, powder coated and spray paint.
  8. Integrated & modularization design: compact structure, easy to installation, maintenance and transportation.
  9. Software control: it can test and display voltage, current, frequency, power factor, active power, reactive power, apparent power etc, the test result can be store & print and form all kinds of curve, chart and test report.

FUNDAMENTAL PARAMETER

Model TRS-LB-0100
Testing Capacity at Three-Phase 415 VAC 0~100 kW
Testing Capacity at single-Phase 240 VAC 0~16.7 kW
Type of Load Resistive, PF=1.0
Duty Continuous
Cooling System 2*550 W Rail Industrial Grade Axial Fan
Phase Available at Both Single-Phase and Three-Phase Conditions
Rated Testing Voltage 415/240 VAC
Rate Frequency 50 Hz
Dimension L*W*H 904*110*1360 mm
Weight 230 kg

FEATURE HIGHLIGHTS

High-level Power Supply Reliability Independent operation to separate main circuit and control circuit, to further meet the actually high-desirable requirement of power supply
Load Step Control Total testing capacity ranges from 0 to the max, consisting of 10kW, 20kW, 50kW, until 100kW load setting switches plus a 0~10kW fine-tuning knob
High-level Protection Mechanism Dual emergency stop button design at both sides to ensure operation reliability
Temperature Monitoring&Control Real-time temperature monitoring display and overheat protection to trigger control circuit disconnection
Rail Industrial Grade Components Components assembled confirm to all relevant standards as top as specified in rail industries